NFPA 701: Description of Test Methods

20.03.2012 § 2 Comments

(No. 2 of 3) The flammability test we use for all of our drapery fabrics is the ACT performance guideline: NFPA 701. The standard actually includes two tests, one for draperies that weigh less than 21 oz./sq. yd (Test Method #1, the replacement for the original small scale test) and a second for draperies that weigh more than 21 oz./sq. yd or have some kind of backing (Test Method #2, the replacement for the original large scale test). « Read the rest of this entry »

NFPA 701: What is the Small Scale Test?

13.03.2012 § Leave a comment

(No. 1 of 3) When referring to drapery fire tests, we often hear people talk about the “vertical fire test” or “small scale”. The actual test code is NFPA 701. (NFPA stands for National Fire Protection Agency.) Since the test is done vertically, compared with, say, ASTM E-84 which is done with the fabric lying horizontally, NFPA 701 is nicknamed the vertical test.

The latest NFPA 701 version was updated in 2010, although its two test methods have hardly changed since 1996. We use NFPA 701 Test Method #1 for lightweight, single layer draperies. In this test, a hanging fabric is exposed to a 4” flame for 45 seconds; whether it passes depend on how much weight the fabric loses when it burns and whether any pieces that break off continue to burn. This second criterion is sometimes called drip burn. « Read the rest of this entry »